Clock
Profil 960
For in do or or out do or mo dels
INSTALLATION AND OPERATING INSTRUCTIONS
When receiving goods please chek nothing is broken otherwise make a claim near shipping company.
B.P. 1
49340 TRÉMENTINES
FRANCE
Tél. : 02 41 71 72 00
Fax : 02 41 71 72 01
www.bodet.com
Réf. : 605775 K
Vista de página 0
1 2 3 4 5 6 ... 19 20

Resumo do Conteúdo

Página 1 - Profil 960

ClockProfil 960For in do or or out do or mo delsINSTALLATION AND OPERATING INSTRUCTIONSWhen receiving goods please chek nothing is broken otherwis

Página 2 - Table of contents

3.5. Independent Quartz clock on mains :Single Face.– Connect mains supply (230VAC) to the terminal (20) of thepower supply unit (ref.933006).– Connec

Página 3 - I - INITIAL VERIFICATION

3.7. Lighting connectionA 10 A fuse or circuit breaker for thelighting power supply should beinstalled and switched off prior to anymaintenance in the

Página 4 - II - INSTALLATION

IV - OPERATING AND TIME SETTINGNOTA : to respect the security rules, the time distribution network must be be SELV-type.- The impulses wires should be

Página 5 - 2.3 Double Face clock

4.1.2. ½ minute and minute serial receiver,- Connect the time distribution network toterminals 1 and 2 on the terminal strip (3).- The terminal 3 of t

Página 6 - Ecl 230V 0.5

4.2. AFNOR/IRIG-B time signal receptionOperating principle of AFNOR HM receiver clock :During 1 hour without reception of the time signal the clock op

Página 7

4.3. France Inter radio receiver clockAntenna connection :Connect the 2 wires of the antenna on the FI andGND terminal.Caution: to avoid interferenc

Página 8 - 3.2. DHF HM 230V clock :

4.5. Independent Quartz on mains with remote keyboardSee the booklet of the remote keyboard, reference : 605198.Attention : in case of a double face c

Página 9

V - TECHNICAL FEATURESReadability : 60m.Dimensions :Profil 960 Indoor Profil 960 OutdoorProfil 960 Double face Indoor Double Face integrated Outdoor

Página 10

France Inter radio receiver clock with synchronous second hand :Permanent power supply : 230V; 70mA.Accuracy : absolute with automatic summer/winter

Página 11

Supply OperatingtemperaturesProtection indexWeightProfil 960 I HM minute// and ½ minute serialreceiver-10°C to +50°C IP401 6,5 kgProfil 960E HM minute

Página 12

Table of contents I - INITIAL VERIFICATION ...3 1.1 Un pack ing the clock ...31.2 Clean ing ...

Página 13

VI - WHAT TO DO IF...? ...CHECK.What to do if...? … Check.– The clock (powered by battery)had stopped.– The battery has run out. Replace the batter

Página 14

ENGLISHI - INITIAL VERIFICATIONThank you for choosing a BODET clock. This product has been carefully designed for yoursatisfaction based on ISO9001 qu

Página 15 - 4.4. DHF clock

impulses on a serial ligne ; it is powered by 240 VAC, with a servo second hand.REC MN 1V5 = the clock is a receiver driven by a control unit “Remote

Página 16

2.2 Single Face outdoor clock- Open the clock by giving the 2 screws (3) aquarter turn with the key (1), and then pull thewhole dial towards you (hing

Página 17 - V - TECHNICAL FEATURES

2.3.1. Double Face integrated clockDrill the support (wall, pillar, ...) to therequired dimensions and fix the bracket.- Unscrew by 10 mm the 2 bolts

Página 18

2.3.2 Clock on keyboard- Drill the support (wall, pillar, ...) to therequired dimensions and then fix thebracket.- If necessary, carry out the various

Página 19

III - POWER SUPPLYInstallation and maintenance of this equipment must be carried out by qualified personnelonly.Electrical installation must comply wi

Página 20 - What to do if...? … Check

3.3. AFNOR HM clock low voltage 6/24VConnect the low voltage (TBT) power supply (6 to 24V AC or DC) to the connectors 1 and 2: maximum 1,5 mm2 wire s